YH-602D communication maintenance power supply
Input voltage:110V/220V/230V/240V Product weight:5KG
Size:255*130*150mm
Product Details

YH-602D communication maintenance power supply  

602D communication maintenance power supply is a single line output of stabilized high accuracy 

DC stabilized power supply. The output voltage and current can be adjusted continuously within the

 rated range. Constant voltage and constant current (CV/CC), automatic switching of working modes. 

Double digital display shows output voltage and current independently. Several protection functions 

include current limitation, voltage reduction, short circuit protection, over-temperature protection, etc. 

The design is applied to production line of the plant, maintenance, laboratories and is also a necessary 

device for the communication industry. 

 

Product parameters

 

Parameters

rated voltage

AC220V  50Hz

Power of complete machine 

170W

Operating environment 

040  relative humidity 80

Storage Temperature 

2080  relative humidity 80

Dimensions 

255*130*150mm

weight

5KG

Performance parameters 

output voltage

Adjustable continuously within 060V

output current

Adjustable continuously within 02A

 (current limitation adjustment when above 0.2A)

output power

120W

Source effect

1mV

load effect 

≤0.33%

Ripple noise

≤3mVrms5Hz ~ 1MHz/≤3mArms

Display accuracy 

0.1V/0.1A/1mA

Protection mode

Over current, short circuit, over temperature protection

Dissipation mode

air cooling


Principle description of constant voltage/constant current CV/CC

 

The operation mode of constant voltage/constant current can be automatically switched depending

 on the comparison result of the load current and limited current value.

a) Constant voltage CV

When the existing current value is smaller than the set output limit current value, the power supply

 is working under the constant voltage mode. The CV indicator light on the front panel is on, the output 

voltage is controlled and it will be the same as the set value. Current changes with the load.

b) Constant current mode (CC)

When the current value exceeds the limit value of the output current, the equipment will work in the

 CC mode. The CC indicator light on the front panel is on, the output current value is controlled to the 

set value. Since the limited output power cannot be overloaded, the output voltage can be lower than 

the set value. When the output current is lower than the set value, the equipment will automatically 

change to CC mode.

 

YH-602D communication maintenance power supply  product display

 


 

 

Home | Company Profile | Products | Shopping Cart | Support | Contact Us Copyright ? 2011 Yihua Store All rights reserved.